Magnetic gripper
Series HPM2000

- Secure hold during EMERGENCY STOP
The battery cell is held securely by the permanent magnet even in the event of a pressure drop - Secure query
The solenoid position and battery cell can be queried to ensure that the battery cell is applied and the solenoid is activated before starting transportation - Safe against uncontrolled discharge
The insulating contact surface prevents the battery cell from discharging uncontrollably via the system
Series features
5 million maintenance-free cycles (max.)
IP54
Magnetic field sensor
Inductive sensor
Single-acting - gripped without pressure

- Mounting and positioning
- via centering pins and thread
- Z-compensation available as an accessory
- Energy supply
- tubeless possible via adapter plate
- Sensing slot
- Querying the solenoid position via magnetic field sensors
- Robust, lightweight housing
- Hard-coated aluminum alloy
- Permanent magnet
- requires no power supply
- Contact plate
- Suitable for battery cell diameter 46 mm
- Insulating against the battery cell
- with centering aid -04-A, without -04-A-01
- Centering aid enables center offset of up to +/-2 mm
- Query battery cell
- Possible via plunger in combination with inductive proximity switch