MFS02-S-KHC-IL
Magnetic Field Sensors
Series MFS
- Position sensor for sensing multiple piston positions on pneumatic cylinders
- continuous position detection over a detection range of up to 50 mm
- Data output analog or via IO-Link
- non-contacting and wear-free for long service life
Technical Data
Detection zone | 0 ... 50 [mm] |
Resolution | 0.01 [mm] |
Required magnetic field strength | 2 ... 20 [mT] |
Repetition accuracy | 0.05 [mm] |
Linearity error | 0.3 [mm] |
Switching function | IO-Link/analog |
Supply voltage | 13 ... 30 [V DC] |
Output voltage | 0 ... 10 [V] |
Continuous current | ≤200 [mA] |
Power consumption max. | 550 [mW] |
Electrical version | DC 4-wire |
Voltage drop | ≤1,0 [V] |
Hysteresis configurable | Yes |
Load resistance min. | 2 [kΩ] |
Teach-in | Yes |
Configurable traverse path | Yes |
Sampling rate | 1 [ms] |
Ready delay | 0.175 [s] |
Connection | Cable with connector |
Fixing thread | M8 |
No. of contacts | 5 |
Nr. of wires x diameter | 4x0,08 [mm²] |
Mounting length | 25,0 [mm] |
Cable length | 0.3 [m] |
Installation type | Cable outlet axial |
Cylinder design | C-slot |
Bending radius for fixed routing, min. | 5xØ |
Bending radius when using a drag chain, min. | 10xØ |
Weight | 0.054 [kg] |
Housing Material | PA |
Shock and vibration resistance | 30 g, 11 ms / 10 … 55 Hz, 1 mm |
Protected against polarity reversal | Yes |
Short-circuit-proof | Yes |
Protection to IEC 60529 | IP67 |
EMC according to EN 60947-5-2 | Yes |
Protection class | III |
MTTFd value | 358 [a] |
TM value | 20 [a] |
Ambient temperature range | -20 ... +70 [°C] |
Communication interface | IO-Link V1.1 |
Communication interface detail | COM3 |
Process data length | 32 [Bit] |
Process data structure position | Bit 16 ... 31 |
Process data structure switching signal | Bit 0 ... 7 |
Cycle count | 1 [ms] |